Product Description
We are a leading manufacturer and supplier of Horizontal Laminar Air Flow Unit. It provides a HEPA filtered clean environment that is ideal for operations requiring a particle-free, bacteria-free, dust free environment. It offers an excellent work space for laboratory appliances, microscopes, sterile drug preparations or application requiring work-in-progress protection from outside potentially harmful contaminants. We manufacture this equipment under the firm guidance of expert supervisors using best quality materials. Easy to install and operate, this Horizontal Laminar Air Flow Unit has ergonomic design for versatile usage.
Features:
- Maximum dimensional stability
- Provides excellent work area for laboratories and other applications
- High efficiency
Application:
Specifications:
- Material : Stainless Steel
- Display : LED Display
- Intensity of illumination : 300 Lux
The idea of Horizontal Laminar Air Flow Unit is to direct the particulates and different contaminations going into from clean room, wind current ought to be at a similar speed and same course is named as laminar wind stream. These cupboards are composed of at least one HEPA channels sans any holes or joints and therefore it keeps working of microscopic organisms from assortment in the working zone. In our Horizontal Laminar Air Flow Unit, the course of the stream which originates from above however changes and is handled agreeing the work in a level bearing. The consistent and enduring stream of air keeps material and item from defilement.
Highlights:
- Flat laminar stream and broad use
- Cleaning of condition
- Satisfied with universal innovation
- High residue holding limit
- CE and ISO guaranteed
Use: The unit is intended for particular work and are customized to the particular necessities of labs, for conveying concoction procedures, therapeutic and pharmaceuticals industry and electronic and mechanical areas.
Directions to utilize: The unit should be composed to the working zone, so pollution can be secured any place vital.
Superior Air Purity and FiltrationThis laminar flow cabinet utilizes a premium HEPA filter paired with a pre-filter, achieving 99.97% efficiency at 0.3 micron. The horizontal airflow creates a protective working zone, keeping samples and processes free from contamination by particulates and dust (<0.01%). Digital monitoring and optional filter clog alarms further safeguard optimal performance.
Ergonomic and Intuitive DesignThe unit boasts a sliding acrylic front door, soft LED or fluorescent illumination (>800 lux), and a stainless steel work surface with a matte finish for glare reduction. Transparent side panels increase visibility, while caster wheels (optional) allow effortless mobility. Maintenance is simplified with front-accessible filters and a smooth, easy-to-clean interior.
Versatile Applications and CustomizationEngineered for microbiology, tissue culture, pharmaceuticals, and laboratory environments, this laminar flow unit is suitable for table-top or benchtop installations. Standard designs fit 1 to 3 users, but flexible customization optionsincluding size, color, and hole configurationensure compatibility with diverse workflows and preferences.
FAQs of Horizontal Laminar Air Flow Unit:
Q: How does the Horizontal Laminar Air Flow Unit ensure a contaminant-free workspace?
A: The unit uses horizontal HEPA-filtered airflow with 99.97% efficiency at capturing 0.3 micron particles, combined with pre-filtration to eliminate dust and contaminants. This creates a continuous sterile environment across the work surface, significantly reducing the risk of contamination.
Q: What are the benefits of the sliding acrylic front door and transparent side panels?
A: The sliding acrylic front door allows easy and safe access to the workspace while minimizing turbulence. Transparent acrylic or polycarbonate side panels maximize visibility and light penetration, enhancing ergonomic comfort during operations.
Q: How and when should the filters be maintained or replaced?
A: Filter maintenance depends on usage frequency and airborne particulate load. The filter clog indicator (optional) and digital airflow monitor help determine when filters require replacement. Typically, filters are checked every 612 months under normal laboratory conditions.
Q: Where is this unit typically used, and for what applications?
A: This laminar flow cabinet is widely used in microbiology, pharmaceutical manufacturing, tissue culture, and cleanroom laboratory settings where specimen integrity and worker protection are essential.
Q: What is the process for installing and powering the unit?
A: Installation is straightforward: place the unit on a benchtop or table, connect the 2-meter power supply cord to a 220V AC, 50 Hz outlet, and activate the digital microprocessor controls. Caster wheels can be fitted for mobile use upon request.
Q: How does the worktable material and finish contribute to maintenance and cleanliness?
A: The stainless steel worktable (SS 304, matt finish) provides a non-porous, smooth surface that is highly resistant to chemicals and easy to disinfect, ensuring a sterile and low-maintenance working area.
Q: What advantages does the digital parameter display offer?
A: The microprocessor-based digital display allows precise monitoring of key parameters like airflow velocity and filter status, promoting reliable operation and timely maintenance, while reducing manual checks.